Skip to content
Solar Account.
Real Estate & Mortgages

How Shoring Building Supports Work on Construction Sites: Engineering, Types, and Safety

Shoring supports construction sites by providing temporary structural stabilization to prevent buildings, walls, or open excavations from collapsing during construction, alteration, or foundation repair. By redistributing structural weight and resisting latera...

How Shoring Building Supports Work on Construction Sites: Engineering, Types, and Safety

Shoring supports construction sites by providing temporary structural stabilization to prevent buildings, walls, or open excavations from collapsing during construction, alteration, or foundation repair. By redistributing structural weight and resisting lateral earth pressure, shoring safely transfers heavy loads to stable ground or structural elements, protecting workers, adjacent properties, and site integrity throughout project lifecycles.

Contents

Fundamental Principles of Construction Shoring

Shoring is a fundamental branch of temporary works engineering in civil construction. Its primary objective is to maintain structural equilibrium when an existing building or newly opened excavation loses its natural self-supporting capacity. This occurs frequently during structural modifications, foundation repairs, deep excavations adjacent to existing structures, or when structural components suffer damage.

At its structural core, shoring works by establishing an alternative load path. When a load-bearing column, foundation footplate, or retaining wall is compromised, removed, or yet to be constructed, the dead loads (the weight of permanent building materials) and live loads (forces from equipment, personnel, and environmental factors) must be intercepted. Shoring systems capture these vertical and horizontal forces and transfer them safely to secondary support structures or directly into stable, load-bearing strata.

Engineers distinguish shoring from related temporary works such as scaffolding and underpinning:

  • Shoring: Mechanically supports existing structural elements or earth faces against collapse by applying static compressive resistance.
  • Scaffolding: Serves primarily as a temporary working platform for access, carrying lightweight operational loads rather than primary structural weights.
  • Underpinning: A permanent modification that deepens or extends an existing foundation to reach stronger soil strata, often relying on temporary shoring while construction is underway.

The design of temporary shoring must account for elastic deformation, material creep, thermal expansion, and dynamic construction vibrations. Failure to calculate these parameters accurately can lead to differential settlement, structural cracking, or catastrophic progressive collapse on the job site.

Primary Types of Building Shoring Systems

Building shoring is categorized based on the geometry of the support elements, the direction of the forces being controlled, and site layout constraints. The three primary building shoring classifications are raking shoring, flying shoring, and dead shoring.

  • Raking Shoring (External Diagonal Support)

    • Wall
    • Cleat
    • Raker (45°-60°)
    • Sole Plate
  • Flying Shoring (Inter-Building Horizontal)

    • Wall to Wall
    • Strut
  • Dead Shoring (Vertical Load Transfer)

    • Wall/Slab
    • Needle Beam
    • Props
    • Sole Plates

1. Raking Shoring (Inclined Support)

Raking shoring utilizes inclined structural members—known as rakers—to provide lateral stability to bulging, cracked, or unstable external walls.

A standard raking system consists of a wall plate secured vertically against the target structure, a series of inclined rakers sloping downward to the ground, and a sole plate embedded firmly into the earth or concrete slab. The optimum angle of inclination for a raker ranges between 45° and 60° relative to the horizontal plane.

To prevent the rakers from pushing upward against the wall face, steel or timber cleats are mortised directly into the wall plate, transmitting the horizontal thrust down through the raker to the sole plate. Single-story walls typically require a single raker, while multi-story structures utilize vertical clusters of rakers converging onto a shared sole plate foundation.

2. Flying Shoring (Horizontal Strutting)

Flying shoring (or house shoring) provides temporary horizontal support between two parallel adjacent buildings when an intermediate building is demolished or under heavy renovation. The key feature of flying shoring is that it leaves the ground level completely clear of structural props, enabling free movement of machinery and site personnel below.

The structural assembly consists of horizontal struts spanning the void between the buildings, supported by wall plates, needles, cleats, and inclined strainers. Strainers push against the wall plates above and below the central horizontal strut, stiffening the assembly against lateral buckling. Flying shoring systems are highly efficient in high-density urban infill developments, where work zones cannot accommodate ground-based support frames.

3. Dead Shoring (Vertical Load Bearing)

Dead shoring is designed specifically to support vertical dead and live loads directly above a wall or structural column that needs to be removed or replaced. This system is essential when creating large open spans in ground-floor retail spaces, replacing decayed timber lintels, or repairing damaged lower-level load-bearing masonry.

The operation involves cutting precise openings (chases) through the wall above the work zone. Heavy structural beams—called needles—are placed horizontally through these openings. Vertical props or shore posts are then positioned underneath both ends of the needle beams, resting on thick timber sole plates or steel distribution pads on the floor slab below. Once the dead shoring setup is fully jacked and wedged into positive bearing contact, the masonry or column beneath the needle can be safely demolished.

Excavation Shoring vs. Structural Building Shoring

While structural building shoring counteracts gravity loads and structural displacement, excavation shoring controls lateral earth pressures created when soil is excavated below natural grade. Excavation failures represent one of the most hazardous events in structural construction, making earth-retention shoring mandatory under federal safety regulations.

  • Excavation Shoring Types

    • Soldier Pile & Lagging

      • H-Beam
      • Timber Lagging
    • Sheet Piling

      • Interlocking Steel Sheets
    • Hydraulic Trench Shield

      • Steel Panel
      • Hydraulic Strut

Soldier Piling and Lagging

Soldier piling relies on vertical steel H-beams driven or drilled into the ground at regular intervals (typically 6 to 10 feet apart) around the excavation perimeter. As soil is excavated in lifts, horizontal timber, concrete, or steel planks (lagging) are fitted between the flanges of the H-beams to retain the exposed soil face. This system is best suited for stable soils with deep water tables.

Sheet Piling

Sheet piling consists of continuous, interlocking steel sheets driven into the soil using vibratory hammers before excavation begins. The interlocking joints form a continuous structural wall that resists lateral earth pressure while restricting groundwater ingress. Sheet piles are standard choice for deep basements, marine construction, and sites with high water tables.

Hydraulic Shoring and Trench Boxes

For pipe trenching and shallow utility work, contractors utilize pre-engineered hydraulic shoring systems or rigid steel trench boxes. Hydraulic systems feature aluminum or steel uprights connected by hydraulic cylinders. Once lowered into a trench, the cylinders are pressurized from ground level, expanding the plates tightly against the trench walls to prevent soil shear. Trench shields, by contrast, act as protective barriers designed to withstand soil collapse rather than prevent soil movement actively.

Key Structural Components and Materials

Modern shoring systems rely on high-yield structural materials engineered to precise load tolerances. Historically constructed from heavy timber beams, modern shoring relies extensively on modular steel and high-tensile aluminum components.

  • Needle Beams: Universal structural steel beams (I-beams or H-beams) inserted horizontally through wall openings to support vertical loads during dead shoring operations.
  • Rakers: Heavy timber timbers, structural steel tubes, or modular aluminum shores placed diagonally to resist lateral structural movement.
  • Sole Plates (Footings): Thick timber baulks or engineered steel spreader plates placed on the ground to distribute localized shoring loads across a wider surface area, preventing soil penetration or concrete crushing.
  • Screw Jacks and Hydraulic Props: Adjustable threaded steel tubes or hydraulic cylinders that allow engineers to apply precise pre-loads to shoring components, ensuring snug fitment without over-stressing the existing structure.
  • Cleats and Wedges: Precision timber or steel wedges driven at junction points to lock members into place and fine-tune structural alignment.
Shoring System Primary Load Vector Common Applications Key Components Structural Complexity
Raking Shoring Diagonal / Lateral Bulging exterior walls, lateral support during basement excavations Wall plates, rakers, cleats, sole plates Moderate
Flying Shoring Horizontal Demolition between adjacent urban structures Horizontal struts, strainers, needles, wall plates High
Dead Shoring Vertical Wall removal, lintel replacement, underpinning support Needle beams, vertical props, sole plates, screw jacks High
Soldier Pile & Lagging Lateral Earth Pressure Deep open-cut building excavations in dry, cohesive soils Steel H-piles, timber lagging, tieback anchors High
Sheet Piling Lateral Earth Pressure & Hydrostatic Excavations near open water or high groundwater tables Interlocking steel sheet piles, walers, struts Very High
Hydraulic Trench Shields Lateral Earth Pressure Pipe laying, trench excavations, utility tie-ins Aluminum uprights, hydraulic struts, shield plates Low to Moderate

Engineering Standards and Technical Calculations

Shoring design requires input from qualified structural and geotechnical engineers. Temporary works cannot rely on arbitrary sizing; they must conform to rigorous building codes and engineering guidelines.

In the United States, structural shoring is governed by standards such as ASCE 37 (Design Loads on Structures During Construction), guidelines set by the Occupational Safety and Health Administration (OSHA 29 CFR 1926 Subpart P for Excavations), and local structural building codes.

  1. Existing Structural Load
  2. Needle Beam
  3. Vertical Props (Prop A and Prop B)
  4. Sole Plate / Spreader Pad
  5. Stable Soil / Sub-base Layer

Critical Calculations Required Before Installation

  1. Dead Load Assessment: Total mass of the supported building element, including structural framing, cladding, floor decks, and permanent fixtures.
  2. Live Load Allowances: Temporary loads induced by workers, tools, stacked materials, and environmental factors such as wind and snow loading during the construction window.
  3. Soil Bearing Capacity ($q_a$): The allowable pressure the soil beneath the sole plate can sustain without undergoing settlement. This determines the surface area required for ground-bearing sole plates: $$\text{Required Area } (A) = \frac{\text{Total Applied Load } (P)}{\text{Allowable Soil Bearing Pressure } (q_a)}$$
  4. Buckling Capacity: Calculation of slender structural props using Euler’s column formula or modern steel interaction equations to prevent sudden lateral buckling under compressive loading: $$P_{cr} = \frac{\pi^2 E I}{(K L)^2}$$ Where $E$ is the material modulus of elasticity, $I$ is the moment of inertia, $L$ is the unbraced length, and $K$ is the column effective length factor.

Safety factors applied to temporary shoring typically range between 1.5 and 3.0, depending on structural predictability, potential hazard exposure, and soil stability variations.

Execution: Installation, Inspection, and Striking Protocols

The successful implementation of building shoring requires strict adherence to sequential execution procedures. Improper installation or rushed striking (removal) of shores remains a primary cause of structural failure on active job sites.

Phase 1: Pre-Installation Verification

Before placing shores, engineers conduct site evaluations using non-destructive testing (such as ultrasonic scanning or concrete coring) to verify the integrity of the existing structure. Geotechnical soundings confirm soil density where sole plates will rest.

Phase 2: Sequential Installation and Pre-Loading

Shoring installation proceeds in a calculated sequence to avoid shocking the structure. Props are erected, plumbed using laser alignment, and gradually pre-loaded using mechanical screw jacks or hydraulic rams.

Pre-loading is critical: it removes mechanical slack within the shoring assembly and transfers the structural load from the wall or slab to the shore before existing supports are removed. Monitoring equipment—such as strain gauges, tilt meters, and optical survey targets—is calibrated at this stage to establish baseline measurements.

Phase 3: Continuous Monitoring and Maintenance

While shoring is under active load, regular inspections are mandated under safety regulations. Inspections occur daily or immediately following high-impact events such as seismic tremors, heavy rainfall, or site blasting operations.

Key inspection parameters include:

  • Checking for timber splitting, steel deformation, or local buckling.
  • Verifying that sole plates remain firmly bedded without differential settlement.
  • Confirming that wedges and screw jacks remain tight under vibration.
  • Monitoring movement indicators for structural displacement exceeding calculated thresholds (typically 2 mm to 5 mm depending on structural sensitivity).
  1. Pre-Installation

    • Geotechnical soil test
    • Structural integrity check
  2. Installation & Pre-Load

    • Erect props & rakers
    • Pre-load hydraulic jacks/screw jacks
    • Lock wedges/cleats
  3. Active Monitoring

    • Strain gauges
    • Daily visual inspections
    • Settlement
  4. Striking (Removal)

    • Verify load transfer
    • Gradual jack release
    • Reverse sequence top-down or bottom-up per engineering plan

Phase 4: Striking (Removal) Sequence

Striking shoring requires equal precision to installation. The structural load must be systematically returned to the permanent structure once new concrete cures or structural steel installation is completed.

Jacks are backed off incrementally across the entire shoring array rather than released at individual points simultaneously. This prevents sudden redistributions of load that could crack newly set concrete or overload adjacent temporary props.

Frequently Asked Questions

What is the primary difference between shoring and underpinning?

Shoring is a temporary structural support system designed to hold up buildings, walls, or earth faces during construction or repair. Underpinning is a permanent engineering intervention that alters, deepens, or expands an existing foundation to increase its load-bearing capacity permanently.

How long can temporary building shoring remain in place?

Temporary shoring is typically designed for project windows ranging from a few weeks to several months. If a project requires shoring to remain active for longer periods (e.g., over six months), engineers must re-evaluate the system for material degradation, steel corrosion, timber decay, and long-term soil creep under sustained stress.

What is the maximum recommended angle for raking shores?

The optimal angle of inclination for raking shores is between 45° and 60° relative to the horizontal plane. Angles steeper than 60° provide insufficient lateral resistance against horizontal thrusts, while angles flatter than 45° generate excessive bending moments in the raker timber/pipe and require longer, less stable members.

Who is legally responsible for designing shoring systems on a construction site?

Shoring designs must be prepared, calculated, and stamped by a licensed Professional Engineer (PE) or Structural Engineer (SE). On-site execution must be supervised by a "Competent Person" as defined by OSHA guidelines—someone capable of identifying hazards and authorized to take prompt corrective action.

How does hydraulic shoring differ from traditional timber shoring?

Hydraulic shoring uses pressurized aluminum or steel cylinders that push outward against trench or wall faces, offering fast installation from outside an excavation. Timber shoring requires manual cutting, placement, and wedging inside the work area, making it more labor-intensive and exposing workers to greater risk during initial setup.

Executing a Site-Specific Shoring Strategy

Deploying shoring building supports requires a structured engineering approach to ensure site safety and structural performance:

  1. Engage Structural and Geotechnical Engineers Early: Perform structural inspections and soil testing prior to excavation or structural modification.
  2. Select System Architecture Based on Structural Dynamics: Match the system to the precise load vector—use dead shoring for gravity loads, raking shoring for lateral building forces, and sheet or soldier piling for deep excavations.
  3. Establish Clear Pre-Loading Protocols: Ensure all temporary props use calibrated screw jacks or hydraulic rams to take up load gradually before primary supports are altered.
  4. Implement Daily Inspections: Inspect props, sole plates, and load indicators daily, particularly after heavy rain or vibration-heavy construction activities.
  5. Maintain Standard Removal Sequences: Never strip shoring prematurely. Confirm that permanent structural elements have reached required design strengths (e.g., concrete cylinder compressive tests) before initiating a controlled, incremental striking process.

By implementing these engineering workflows, project managers and structural contractors safeguard site crews, protect adjacent historic or modern structures, and maintain structural stability through every phase of construction.

Written by

Elizabeth Ward

Real Estate & Housing Analyst